NUSORB® KOGC TECHNICAL DATA SHEET

Raw Material:

Coal

Activation Method:

High Temperature Steam

Particle Type:

Pellets

General Specifications:

Particle Size US Sieve (ASTM D2862)
Available as 1.5, 3 and 4 mm Diameter Pellets
Apparent Density (ASTM D2854) 0.55 g/ml Typical
Moisture (ASTM D2867) 15% Typical
Hardness (ASTM D3802) 98% Typical
Surface Area (BET) (On Base Material) (ASTM D2867) 1000 m2/g Typical
CCl4 Activity (ASTM D3467) (On Base Material) 60% Typical
H2S Loading, Minimum 0.15  (1)
(1)

 

 

As determined by NUCON, where in a moist air stream containing 1% H2S at a total flow rate of 1450 ml/min is passed through a 1 inch diameter, 9 inch deep column of KOGC and monitored to 50 ppm H2S breakthrough. Carbon is ground to a standard particle size for testing.

Information herein is accurate to the best of our knowledge. User should determine the suitability of the product for the intended use; liability consists of replacing product. NUCON International, Inc., does not suggest violation of any existing patents or give permission to practice any patented invention without a license.

IMPORTANT SAFETY INFORMATION
CAUTION: OXYGEN IS REMOVED FROM AIR BY WET ACTIVATED CARBON.

Oxygen may be rapidly reduced to a hazardous level in closed or partially closed tanks, receptacles or other enclosed spaces containing carbon. When entering any enclosed space regardless of its contents, follow recommended safety procedures
(See MCA Safety Guide SG-10, "Recommended Safe Practices and Procedures, Entering Tanks and Other Enclosed Spaces", Mfrg. Chem. Assoc., 1825 Connecticut Ave., N.W., Washington, D. C., 20009).

For additional information contact:
NUCON International, Inc.
7000 Huntley Road

Columbus, OH 43229 U.S.A.
Telephone: 614-846-5710  Fax: 614-431-0858
http//www.nucon-int.com/

NUSORB® and KOGC™
are Registered Trademarks of NUCON International, Inc.