Noble Gas Delay Adsorbents
NUCON supplies a series of NUSORB® carbons for noble gas delay for both BWR and PWR nuclear power plants. These products have are in extremely successful use around the world. The NUSORB G30 series of noble gas delay carbons is available in a number of standard particle sizes. Custom sizes are available when your application requires a non-standard particle size. NUCON has the ability to not only supply these fine grades of carbon but has developed a comprehensive body of data on specific radioisotope delay characteristics for many temperature, moisture, Relative Humidity and flow parameters. NUCON can provide the actual filling services for the large noble gas delay vessels. To achieve system design performance the carbon must be loaded with great care to eliminate moisture pickup and to achieve the design packing density. NUCON has the experience and equipment to ensure these critical parameters are met. Our radioisotope laboratory can develop any specific test data required for your specific applications. NUCON has over 25 years of experience testing noble gas delay carbons for our in-house R&D and Quality Control requirements. We have even provided testing for competing carbon suppliers since they did not have a radioisotope laboratory. For comprehensive technical and performance data on our NUSORB® G30 series noble gas delay carbon please request NUCON Bulletin 11B10 or download as a PDF [495 KB].
NUSORB® is a registered Trade Mark of NUCON International, Inc. NUCON International Inc. All Rights Reserved |