| NUCON |
|
|
NUCON International, Inc.
7000 Huntley Road Columbus, OH 43229-1035 U.S.A.
Telephone: 614-846-5710 Fax: 614-431-0858 E-mail sales@nucon-int.com |
 |
|
|
NUSORB® KITEG
IITM
CARBON TECHNICAL DATA SHEET
RADIOIODINE REMOVAL
PERFORMANCE
|
| Test
conditions |
Guaranteed
Performance |
Typical
Performance |
|
I2 (elemental),
30°C, 95% RH
|
<0.1% penetration |
0.05% penetration |
|
I2 (elemental)
retention, 180°C
|
>99.5 % (loading plus
elution) |
>99.9% (loading plus
elution) |
|
Methyl iodide, 25°C, 95% RH
|
<1.0% penetration |
<0.5% penetration |
|
Methyl iodide, 30°C, 95% RH
|
<1.0% penetration |
<0.5% penetration |
|
Methyl iodide, 80°C, 95% RH
|
<0.5% penetration |
<0.10% penetration |
|
Methyl iodide, 130°C, 95% RH
|
<1.0% penetration |
<0.10% penetration |
| Carbon Tetrachloride Activity
(ASTM D3467) |
60 % Minimum on base carbon |
| Ash Content (ASTM D2866) |
4% Maximum on base carbon |
| Apparent Density (ASTM
D2854) |
0.50-0.54 g/ml |
| Hardness (ASTM D3802) |
98% Minimum |
| Ignition Temperature (ASTM
D3466) |
340°C Minimum |
| Impregnant Content (by
extraction) |
5% Maximum (reacted Iodine and
Amine Salts) |
|
Particle Size Distribution
U.S. Sieves (ASTM D2862)
|
| On 6 Mesh |
0.1% Maximum |
| On 8 Mesh |
5.0% Maximum |
| 8 x 12 Mesh |
60% Maximum |
| 12 x 16 mesh |
40% Minimum |
| Thru 16 Mesh |
5.0% Maximum |
| Thru 18 Mesh |
1.0% Maximum |
|
NUSORB® KITEG
IITM
satisfies US NRC Reg. Guides 1.52 and/or
1.140 requirements.
|
|
These product specifications are based
on the latest US NRC requirements for
"Engineered Safety Feature" systems.
1. US NRC Regulatory Guide 1.52,
Rev 2, March 1978; "Design, Testing
and Maintenance Criteria for
Engineered Safety Feature Atmosphere
Cleanup System Air Filtration and
Adsorption Units of
Light-Water-Cooled Nuclear Power
Plants."
2. US NRC Regulatory Guide 1.140,
Rev. 1, October 1979; "Design,
Testing, and Maintenance Criteria for
Normal Ventilation Exhaust System Air
Filtration and Adsorption Units of
Light-Water-Cooled Nuclear Power
Plants."
3. ASTM D3803-89; "Standard Method
For Radioiodine Testing of Nuclear
Grade Gas Phase Adsorbents."
4. ANSI/ASME N509, Table 5.1;
"Nuclear Power Plant Air-cleaning
Units and Components." (all
editions)
5. ANSI/ASME AG-1, Section FF;
"Code on Nuclear Air and Gas
Treatment."
Information herein is accurate to
the best of our knowledge. User
should determine the suitability for
the product for the intended use;
NUCON® liability
consists of replacing product.
NUCON® does not
suggest violation of any existing
patent or give permission to practice
any patented invention without a
license.
Standard pricing and acceptance of
orders are based on supply of
material and documentation according
to client specification of one (1)
performance standard. Supply of
material and documentation conforming
to two (2) or more performance
standards may require additional
testing and be subject to additional
fees.
IMPORTANT SAFETY
INFORMATION
CAUTION: OXYGEN IS REMOVED FROM AIR BY
WET ACTIVATED CARBON.
Oxygen may be rapidly reduced to a
hazardous level in closed or partially
closed tanks, receptacles or other
enclosed space containing carbon. When
entering any enclosed space, regardless
of its contents, follow recommended
safety procedures (see MCA Safety Guide
SG-10, "Recommended Safe Practices and
Procedures, Entering Tanks and Other
Enclosed Spaces", Mfrg. Chem. Assoc.,
1825 Connecticut Ave., N.W., Washington,
D.C., 20009).
|
|
For additional
information contact:
NUCON International, Inc • 7000
Huntley Road • Columbus, OH 43229
• U.S.A.
Telephone: +614-846-5710 • Fax:
+614-431-0858 •
http://www.nucon-int.com/
|
|
|
[Home Page],
[Activated Carbon],
[Filter System Testing Services],
[Testing Instruments]
[Nuclear Power Plant Services],
[Laboratory Testing Services],
[DOE & Defense Facility services],
[Solvent Vapor Recovery Systems],
[Company Profile & Experience],
[Site Map],
[Employment]
NUCON International Inc. All Rights Reserved
|