TECHNICAL DATA SHEET
RADIOIODINE REMOVAL PERFORMANCE
| Test conditions |
Guaranteed Performance |
Typical Performance |
| I2 (elemental), 30°C, 95% RH |
<0.1% penetration |
0.05% penetration |
| I2 (elemental) retentation,
180°C |
>99.5 % (loading plus elution) |
>99.9% (loading plus elution) |
| Methyl iodide, 25°C, 95% RH |
<1.0% penetration |
<0.5% penetration |
| Methyl iodide, 30°C, 95% RH |
<1.0% penetration |
<0.5% penetration |
| Methyl iodide, 80°C, 95% RH |
<0.5% penetration |
<0.10% penetration |
| Methyl iodide, 130°C, 95% RH |
<1.0% penetration |
<0.10% penetration |
Physical Properties
| Carbon Tetrachloride Activity (ASTM D3467) |
60 % Minimum on base carbon |
| Ash Content (ASTM D2866) |
4% Maximum on base carbon |
| Apparent Density (ASTM D2854) |
0.50-0.54 g/ml |
| Hardness (ASTM D3802) |
98% Minimum |
| Ignition Temperature (ASTM D3466) |
340°C Minimum |
| Impregnant Content (by extraction) |
5% Maximum (TEDA - triethylene diamine) |
Particle Size Distribution
U.S. Sieves (ASTM D2862)
| On 6 Mesh |
0.1% Maximum |
| On 8 Mesh |
5.0% Maximum |
| 8 x 12 Mesh |
60% Maximum |
| 12 x 16 mesh |
40% Minimum |
| Thru 16 Mesh |
5.0% Maximum |
| Thru 18 Mesh |
1.0% Maximum |
NUSORB® TEGTM satisfies US NRC
Reg. Guides 1.52 and/or 1.140 requirements.
These product specifications are based on the latest US NRC requirements for
"Engineered Safety Feature" systems.
1. US NRC Regulatory Guide 1.52, Rev 2, March 1978; "Design, Testing and
Maintenance Criteria for Engineered Safety Feature Atmosphere Cleanup System Air
Filtration and Adsorption Units of Light-Water-Cooled Nuclear Power Plants."
2. US NRC Regulatory Guide 1.140, Rev. 1, October 1979; "Design, Testing, and
Maintenance Criteria for Normal Ventilation Exhaust System Air Filtration and Adsorption
Units of Light-Water-Cooled Nuclear Power Plants."
3. ASTM D3803-89; "Standard Method For Radioiodine Testing of Nuclear Grade Gas
Phase Adsorbents."
4. ANSI/ASME N509, Table 5.1; "Nuclear Power Plant Air-cleaning Units and
Components." (all editions)
5. ANSI/ASME AG-1, Section FF; "Code on Nuclear Air and Gas Treatment."
Information herein is accurate to the best of our knowledge. User should determine the
suitability for the product for the intended use; NUCON® liability consists of
replacing product. NUCON® does not suggest violation of any existing patent or
give permission to practice any patented invention without a license.
Standard pricing and acceptance of orders are based on supply of material and
documentation according to client specification of one (1) performance standard. Supply of
material and documentation conforming to two (2) or more performance standards may require
additional testing and be subject to additional fees.
IMPORTANT SAFETY INFORMATION
CAUTION: OXYGEN IS REMOVED FROM AIR BY WET ACTIVATED CARBON.
Oxygen may be rapidly reduced to a hazardous level in closed or partially closed tanks,
receptacles or other enclosed space containing carbon. When entering any enclosed space,
regardless of its contents, follow recommended safety procedures (see MCA Safety Guide
SG-10, "Recommended Safe Practices and Procedures, Entering Tanks and Other Enclosed
Spaces", Mfrg. Chem. Assoc., 1825 Connecticut Ave., N.W., Washington, D.C., 20009).
For additional information contact:
NUCON International, Inc 7000 Huntley Road Columbus, OH
43229 U.S.A.
Telephone: +614-846-5710 Fax: +614-431-0858 http://www.nucon-int.com/
[Home Page],
[Activated Carbon],
[Filter System Testing Services],
[Testing Instruments]
[Nuclear Power Plant Services],
[Laboratory Testing Services],
[DOE & Defense Facility services],
[Solvent Vapor Recovery Systems],
[Company Profile & Experience],
[Site Map],
[Employment]
NUCON International Inc. All Rights Reserved
|