Model F-1000-DD Aerosol Detector

For Aerosol (DOP) Testing of HEPA Filtration Systems. Also Works with Polyalphaolefin (PAO).

The NUCON Model F is a truly portable portable detection instrument combining current solid-state photodiode technology with precision optical components. the result is a rugged, reliable, accurate, state-of-the-art particulate detection instrument.

  • Preset CAL for 100 micro g/liter Aerosol Concentration
  • Switchable auto-ranging
  • 1 cfm Sampling Rate
  • Built-In Linearity Check
  • Linear Range 106 : 1
  • Matched Photodiode Sensor and Lamp Characteristics
  • Response Range 2 x 106 : 1
  • Power Supply Regulated to 0.01%
  • 100% Solid-State Electronics
  • Optional Hand Probe
  •  

    Testing Applications F1000DD_F1 copy4.jpg (11616 bytes)
    • Biohazard Cabinetry
    • Lab Hoods/Exhausts
    • Nuclear Air Cleaning Systems
    • Protective mask Fit Testing
    • Clean Rooms
    • HEPA Filter Systems
    Optics Assembly
    One of the classical methods of aerosol detection is the use of  forward light scattering photometry. A light source is used to produce a cone of light with a dark center and a light sensitive element is placed in the dark area. Light scattering caused by the presence of aerosols increases the current in the light sensitive element proportional to the concentration of aerosols. Originally, photomutliplier tubes (PMT) were used as the light sensitive element. However, because of inherent drawbacks of the PMT, NUCON uses the more reliable photodiode

    The NUCON Model F aerosol detector designed specifically for field use is based on this classic forward light scattering principle, but uses modern matched components to assure reliable measurements at high sensitivity.