F-1000™ Series Test Instruments  
NUCON ®

Model SAE
Halide Detector

ALSO WORKS WITH
HCFC-123

For In-Place Halide* Leak Testing of
Carbon (Charcoal) Filtration Systems

SAE-01c.gif (49917 bytes)

F-1000-HD
Halide Detector

Testing Applications

The NUCON Model SAE is the only continuous Halide detector available thet meets ANSI/ASME standards N510 and AG-1. The model SAE can be calibrated for Vppb level detection of two most commonly used challenge Halides (R-11 and R-12)
  • Nuclear air and Gas Treatment Systems (Safety and Non-Safety Grade)
  • High Efficency Carbon (Charcoal) Air Filtration Systems
  • Lab Fume Hoods/Exhaust
  • Vapor Removal/ Scavenger Systems
  • CFC Detection
  • Switchable Vppm/Vppb Ranges
  • Direct Continuous Real Time Readout
  • External "Zero" Air Filters For Easy Change-Out
  • Automatic Sample Flow Control
  • Recorder Output
  • Built-In Clock/Chronograph
  • Solid-State Electronics

*R-11, R-12, SF6 and others

 

The NUCON® Model SAE Halide Detector is designed for field use. Operations, calibration and maintenace features make this detector easy to use and transport. Real time continuous display elimniates any need for "time-zero" calculation.

SAE-03a.jpg (6228 bytes)

SAE-02a.jpg (7805 bytes)

F-1000-HD, Model SAE Front Panel Cushioned Transportation Storage Case
Technical Specifications and Information:
Sensitivity to Halides:
1 Vppb

Sampling Volume:
2000 ml/min
(Electronically Stabilized)

Linear Range:
1Vppb to 40 Vppm
Reponse Range:
1 Vppb to 80 Vppm

Accuracy:
±10%

Recorder Output:
2.0 V.  1mA
(Short-circuit protected)
Size:
5.3" (13 cm) H x 18" (44 cm) L
x 10.6" (27 cm) D

Weight:
23 lbs. (10.5 Kg)

Power Requirements:
100VA, 120VAC ±10%, 60Hz.
(220VAC, 50 Hz also available)

SAE-04.jpg (8504 bytes)

NUCON® F-1000™
Series Test Instruments

  • Model F Aerosol Generator (Thermal)
  • Model F Halide Generator
  • Model SN-10 Aerosol Generator (Pneumatic)
  • Model F Aerosol Detector
  • Model SAE Halide Detector
  • Model PD-C Pressure Detector
  • Model HGP-H Pulse Mode Halide Generator