Adsorber Tray and Cell Refilling Services
Nucon International, Inc. (NUCON) inspection, refilling and testing procedures ensure a refilled adsorber that meets the requirements of ASME AG-1 ANSI/ASME N509, AACC CS-8T and US NRC Regulatory Guides 1.52 and 1.140. Both Type I and Type II cells can be refilled.
The basic refilling service includes:
- Receipt inspection by NUCON QA to determine "as-found" condition. If any adsorbers are found to be damaged, the client is notified for disposition.
- Removal of old gaskets and/or sealing pads.
- Filling adsorbers with adsorbent meeting customer technical requirements. (Per NUCON Proc. 11-3)
- Installation of new gaskets and/or sealing pads.
- Performance of pressure drop and R-11 leak test (Per NUCON Proc. 11-05)
- Applying refilling label to adsorber
- Repackaging adsorbers in customer's boxes or containers, when sure are reusable and conform to ANSI N45.2. Packaging includes new plastic wrap (0.006 inch thick).
- Supplying COC on adsorbent, gaskets and/or sealing pads and hardware and certified adsorber test results.
- Supplying to customer, if requested, a one quart same of the adsorbent batch used for filling, for test canisters.
|